Specification:
Temperature range of high-temperature bath: RT~160 ℃
Temperature control accuracy of high temperature bath: ± 0.1 ℃ (150 ℃)
Temperature range of low-temperature tank: - 28~100 ℃
Temperature control accuracy of low-temperature tank: ± 0.1 ℃
Outline dimension of high-temperature tank: 600*425* 600 mm
External dimension of low-temperature tank: 230*420*610 mm
Net weight of high temperature tank: 48kg (excluding heat conduction medium)
Net weight of low-temperature tank: 28kg (excluding heat conduction medium)
Power supply: AC 220V 50/60Hz
Test Method:
At present, there are many kinds of fogging test standards for automotive interior materials at home and abroad. These standards involve three test methods: glossiness method, weight method and fogging method
See the following table for various standards and test methods involved:
Standard #
|
Full Name
|
Test methods
|
VW PV3015
|
Determination of Condensate Components
|
Gravimetric method
|
VW PV3920
|
Determination of haze value of non-metallic interior materials
|
Haze method
|
Toyota TSM0503G
|
Determination of Condensate Components
|
Gloss method, weight method
|
Germany DIN 75201
|
Determination of atomization performance of materials used in automotive internal equipment
|
Gloss method, weight method
|
USA SAE J1756[2]
|
Test Method for Determining the Fog Characteristics of Automotive Interior Trim Parts
|
Gloss method, weight method
|
GB ISO 6452
|
Rubber, plastics, artificial leather-Determination of haze characteristics of automotive interior parts
|
Gloss method, weight method
|
GB QB/T 2728[3]
|
Physical and mechanical tests of leather - Determination of atomization performance
|
Gloss method, weight method
|
Test method of atomizer
A.Gloss method: The gas evaporated by heating the sample in the fogging cup is condensed on the low-temperature glass plate. The fogging value of the sample can be obtained by comparing and calculating the glossiness value of the glass plate before and after condensation.
B.Fog method: the gas evaporated by heating the sample in the fogging cup is condensed on the low-temperature glass plate. The fogging value of the sample can be obtained by comparing and calculating the haze value of the glass plate before and after condensation. (purchased separately)
C.Gravimetric method: the gas evaporated by heating the sample in the fogging cup is condensed on the low-temperature aluminum foil. The weight of the sample atomization-condensate can be obtained by weighing the weight changes of the aluminum foil before and after condensation. (Balance to be purchased separately)